ENGLISH | 中文
Hot line:021-37825236
Current position:Home > Products > Fixed Gas Detection > Sensepoint XCD
Sensepoint XCD Transmitter (without Sensor) SPXCDALMTXO
Sensepoint XCD Transmitter (without Sensor) SPXCDALMTXO

产品分类:Sensepoint XCD

产品型号:

产品品牌:

产品备注:

详情说明
SPXCDALMTXO - XCD O2 Transmitter (Without Sensor), 4 To 20 MA Output, ATEX/IECEx/Asian Approvals, 2 X M20 Entries, Painted LM25, Includes Nylon Weather Protection


SPXCDALMTXT - XCD Toxic Transmitter (Without Sensor), 4 To 20 MA Output, ATEX/IECEx/Asian Approvals, 2 X M20 Entries, Painted LM25, Includes Nylon Weather Protection


SPXCDALMTXF - XCD IR & Flammable Transmitter (Without Sensor), 4 To 20 MA Output, ATEX/ IECEx/Asian Approvals, 2 X M20 Entries, Painted LM25, Includes Nylon Weather Protection


SPXCDASMTXO - XCD O2 Transmitter (Without Sensor), 4 To 20 MA Output, ATEX/IECEx/Asian Approvals, 2 X M20 Entries, Painted 316SS, Includes Nylon Weather Protection


SPXCDASMTXT - XCD Toxic Transmitter (Without Sensor), 4 To 20 MA Output, ATEX/IECEx/Asian Approvals, 2 X M20 Entries, Painted 316SS, Includes Nylon Weather Protection


SPXCDASMTXF - XCD IR & Flammable Transmitter (Without Sensor), 4 To 20 MA Output, ATEX/ IECEx/Asian Approvals, 2 X M20 Entries, Painted 316SS, Includes Nylon Weather Protection


SPXCDALMTXOM - XCD O2 Transmitter (Without Sensor), 4 To 20 MA And Modbus Output, ATEX/ IECEx/Asian Approvals, 2 X M20 Entries, Painted LM25, Includes Nylon Weather Protection


SPXCDALMTXTM - XCD Toxic Transmitter (Without Sensor), 4 To 20 MA And Modbus Output, ATEX/IECEx/Asian Approvals, 2 X M20 Entries, Painted LM25, Includes Nylon Weather Protection


SPXCDALMTXFM - XCD IR & Flammable Transmitter (Without Sensor), 4 To 20 MA And Modbus Output, ATEX/IECEx/Asian Approvals, 2 X M20 Entries, Painted LM25, Includes Nylon Weather Protection


SPXCDASMTXOM - XCD O2 Transmitter (Without Sensor), 4 To 20 MA And Modbus Output, ATEX/ IECEx/Asian Approvals, 2 X M20 Entries, Painted 316SS


SPXCDASMTXTM - XCD Toxic Transmitter (Without Sensor), 4 To 20 MA And Modbus Output, ATEX/IECEx/Asian Approvals, 2 X M20 Entries, Painted 316SS


SPXCDASMTXFM - XCD IR & Flammable Transmitter (Without Sensor), 4 To 20 MA And Modbus Output, ATEX/IECEx/Asian Approvals, 2 X M20 Entries, Painted 316SS


SPXCDULNTXO - XCD O2 Transmitter (Without Sensor), 4 To 20 MA Output, UL/C-UL/INMETRO, 2 X 3/4" NPT Entries, Painted LM25, Includes Nylon Weather Protection


SPXCDULNTXT - XCD Toxic Transmitter (Without Sensor), 4 To 20 MA Output, UL/C-UL/INMETRO, 2 X 3/4" NPT Entries, Painted LM25, Includes Nylon Weather Protection


SPXCDULNTXF - XCD IR & Flammable Transmitter (Without Sensor), 4 To 20 MA Output, UL/C-UL/INMETRO, 2 X 3/4" NPT Entries, Painted LM25, Includes Nylon Weather Protection


SPXCDUSNTXO - XCD O2 Transmitter (Without Sensor), 4 To 20 MA Output, UL/C-UL/INMETRO, 2 X 3/4" NPT Entries, Painted 316SS, Includes Nylon Weather Protection


SPXCDUSNTXT - XCD Toxic Transmitter (Without Sensor), 4 To 20 MA Output, UL/C-UL/INMETRO, 2 X 3/4" NPT Entries, Painted 316SS, Includes Nylon Weather Protection


SPXCDUSNTXF - XCD IR & Flammable Transmitter (Without Sensor), 4 To 20 MA Output, UL/C-UL/INMETRO, 2 X 3/4" NPT Entries, Painted 316SS, Includes Nylon Weather Protection


SPXCDULNTXOM - XCD O2 Transmitter (Without Sensor), 4 To 20 MA And Modbus Output, UL/C-UL/INMETRO, 2 X 3/4" NPT Entries, Painted LM25, Includes Nylon Weather Protection


SPXCDULNTXTM - XCD Toxic Transmitter (Without Sensor), 4 To 20 MA And Modbus Output, UL/C-UL/INMETRO, 2 X 3/4" NPT Entries, Painted LM25, Includes Nylon Weather Protection


SPXCDULNTXFM - XCD IR & Flammable Transmitter (Without Sensor), 4 To 20 MA And Modbus Output, UL/C-UL/INMETRO, 2 X 3/4" NPT Entries, Painted LM25, Includes Nylon Weather Protection, Includes Nylon Weather Protection


SPXCDUSNTXOM - XCD O2 Transmitter (Without Sensor), 4 To 20 MA And Modbus Output, UL/C-UL/INMETRO, 2 X 3/4" NPT Entries, Painted 316SS, Includes Nylon Weather Protection


SPXCDUSNTXTM - XCD Toxic Transmitter (Without Sensor), 4 To 20 MA And Modbus Output, UL/C-UL/INMETRO, 2 X 3/4" NPT Entries, Painted 316SS, Includes Nylon Weather Protection


SPXCDUSNTXFM - XCD IR & Flammable Transmitter (Without Sensor), 4 To 20 MA And Modbus Output, UL/C‐UL/INMETRO, 2 X 3/4" NPT Entries, Painted 316SS, Includes Nylon Weather Protection






Sensepoint XCD




Transmitter provides comprehensive monitoring of combustible, toxic and Oxygen gas hazards in potentially explosive atmospheres - indoors and outdoors.




Features&Benefits




All-in-one gas monitoring solution
Proven SurecellTM electrochemical sensors
Global approvals
QuickSpecs




Input voltage range: 16 to 32 VDC (24 VDC nominal)
Communication: RS485, MODBUS RTU
Certified temperature range: 40° to +149°F (-40° to +65°C)
 ProductOveriew




Sensepoint XCD now has remote monitoring capabilities for its toxic and Oxygen sensors. Its remote capability is designed to offer excellent flexibility of use and is an ideal solution for hard-to-reach locations or areas where the transmitter needs to be separate from the sensor. With remote toxic and Oxygen sensor mounting of up to 100 feet (30m) away from the transmitter, Sensepoint XCD provides a robust monitoring solution even in challenging environments where detection is difficult, including applications where the point of detection is in an area that is not easily accessible or where the detector would not be visible, like in high or low level concealed areas or outside a room being monitored.   




Sensepoint XCD is easy to use. The sensor simply plugs into the bottom of the transmitter and the transmitter automatically configures itself accordingly. Users can modify detector operation using the LCD and magnet switches without ever needing to open the unit. This enables one-man, non-intrusive operation and reduces routine maintenance time and costs.  



A tri-color backlit LCD clearly indicates the unit’s status at a glance, even from a distance. A steady green backlight indicates normal operation, flashing yellow indicates fault and flashing red indicates an alarm. 




All detectors are supplied pre-configured and include two programmable alarm relays, one programmable fault relay as well as an industry standard 4-20mA output (sink or source selectable) and MODBUS communication. The scale, range, relay operation, alarm set point and electronic tag number of the detector can be adjusted using the transmitter's LCD and non-intrusive magnetic switches. Outputs are automatically inhibited during adjustment, thereby reducing the risk of false alarm at the control panel during maintenance. 




In addition to the standard XCD Detector supplied including one of three types of plug in stainless steel sensor, we offer the XCD Sensors
and Transmitter assembly separately. This is typically required on larger projects where it is planned to order the transmitter and the sensors separately due to the sensors limited shelf life. These sensors simply plug into the socket at the bottom of the transmitter and the transmitter recognises the sensor type and automatically configures itself accordingly. A bump or gassing test should be performed to validate the function of XCD Assembly. 




Additional Features and Benefits: 




All-In-One Gas Monitoring Solution 




Flammable (catalytic or infrared), toxic and oxygen versions available  
Serves new/retrofit, indoor/outdoor applications  
Stainless steel or aluminum explosion-proof housing options  
IP66 as standard 
Proven and Reliable Sensor Technology 




SurecellTM electrochemical sensors  
Poison immune infrared sensors  
Poison resistant catalytic bead sensors  
Long life sensors 
Global Approvals 




US and Latin America, European, Canadian and Asian
Compliant with UL, INMETRO, ATEX,  IECEx, CSA, KTL, PA, GB and CCCF standards 
Easy to Use  
User friendly and intuitive tri-color backlit display with digits, bar graph and icons  
Fully configurable via magnetic switches  
Optional remote sensor mounting  
Selectable sink or source 4-20mA output  
Auto-inhibit during maintenance  
MODBUS communications for remote diagnostics/configuration 
Cost Effective  
Common transmitter platform  
Minimal training required  
Reduced spares  
Non-intrusive, one-man operation  
Plug-in sensor replacement  
MODBUS multi drop option offers cabling savings 
Simple Installation  
Plug-in display module removes to give access to terminal area  
Integral mounting bracket  
2 x M20 or ?” NPT cable/conduit entries                      
Removable plug/socket type terminal blocks for               
Sink/source switch to suit preferred wiring topology  
Integral mounting plate attaches to surface, horizontal or vertical piping





Click:
请先加QQ再询价
服务热线
微信公众账号

二维码